WRDDL Pune · West Zone

Dr. Rajbir Singh

Lab Director

Test Management

2 pending ·3 in progress ·3 completed

2

Pending

3

In Progress

3

Completed

2

Overdue

Test CodeTest NameSample IDCategoryAnalystMethod / InstrumentResultStatus
BACT-BRU-001Brucella Rose Bengal Test2026-04-1287BacteriologyDr. Navjot SinghRose Bengal Plate Agglutination
Manual

Ref: Negative
In Progress
SERO-BRU-002ELISA - Brucella IgG2026-04-1287SerologyDr. Navjot SinghIndirect ELISA
ELISA Reader - BioTek ELx800

Ref: <0.2 Negative
Pending
HAEM-HB-001Haemoglobin Estimation2026-04-1288HaematologyTechnician RanjitSahli's Method
Haemoglobinometer
8.2 g/dL
Ref: 8.0-15.0 g/dL
Completed
HAEM-TLC-001Total Leukocyte Count2026-04-1288HaematologyTechnician RanjitNeubauer Chamber
Microscope - Olympus CX43
12,400 cells/µL
Ref: 4,000-12,000
Completed
VIRO-PPR-001PPR Antigen ELISA2026-04-1289VirologyDr. Simran GillSandwich ELISA
ELISA Reader - BioTek ELx800

Ref: >50% Positive
In Progress
MOL-PPR-001RT-PCR PPR2026-04-1289MolecularDr. Simran GillReal-Time RT-PCR
CFX96 Bio-Rad

Ref: <35 Positive
Pending
VIRO-RAB-001FAT - Rabies2026-04-1292VirologyDr. Simran GillFluorescent Antibody Test
Fluorescence Microscope - Nikon Eclipse
Positive
Ref: Negative
Approved
SERO-GLA-001CFT - Glanders2026-04-1293SerologyDr. Navjot SinghComplement Fixation Test
Manual - Water Bath

Ref: <1:5 Negative
In Progress